Battery temperature chamber for cell testing
MZTC: Multi-Zone Temperature Chamber for Battery Cell Testing
The MZTC is a compact temperature chamber with 4 or 8 separate zones. Each zone holds one battery tray and is controlled independently between 10 °C and 60 °C, so cells can be tested at different temperatures at the same time.
Used next to an Arbin battery tester and controlled from MITS software, or stand-alone with the built-in touchscreen.
What the MZTC looks like
The chamber is 318 mm wide and stands on a bench or in a rack. Each zone has its own battery tray, which slides in from the front.
1
2
3
4
5
6
7
- 1Touchscreen. Shows the set temperature and the measured temperature of every zone, and is used to set them when the chamber runs stand-alone.
- 2Zone. Each zone is insulated from the others and has its own temperature set point.
- 3Rotary door locks. Two locks hold each tray in place and keep the zone closed.
- 4Connectors. The cable from the tester channel plugs into the front of the tray.
- 5Open zone. The inside of each zone is stainless steel.
- 6Battery tray. The tray holds the cell and slides into the zone. Different trays are available for coin, cylindrical and pouch cells.
- 7Pressure relief valve. Each tray has a valve in the centre of its front panel, which opens if a cell releases gas.
How the MZTC works
Put the cell in a tray
Choose the tray for your cell: coin cell, cylindrical cell, or a universal tray for pouch cells. The tray holds the cell and makes the electrical contact.
Slide the tray into a zone and lock it
Two rotary locks close the zone. The connectors are on the front of the tray, so the cable from the tester plugs in from outside.
Set the temperature for that zone
Set each zone in the Arbin MITS software, or on the touchscreen. Each zone can have a different temperature.
Three ways to use the MZTC
The chamber is the same in each case. What changes is what it is connected to, and where the zone temperatures are set.
The MZTC in customers' labs
An example: one test at eight temperatures
Eight cells are placed in an 8-zone MZTC, one cell in each zone, and connected to the eight channels of an Arbin LBT tester. Every zone is given a different set point, from 15 °C to 50 °C, and all eight cells run the same test schedule at the same time.
The results for the eight temperatures can then be compared directly, because the cells were tested on the same days on the same tester. With a single conventional chamber the same study would need eight runs, one after the other.

MZTC chamber models
There are three chambers. They work in the same way and differ in the number and size of the zones, so the choice depends on your cells.
Full specifications are in the MZTC catalog. Ask us for the catalog →
Battery trays and cell formats
Trays are sold separately and chosen to match your cells and test current. Every tray works from 10 °C to 60 °C and has a pressure relief valve.
The full list of trays and cables is in the MZTC catalog. Ask us for the catalog →
Features and safety
功能介绍
- ✓4 or 8 independent zones are isolated and allow a unique temperature set point.
- ✓The patented design gives a stable and uniform temperature for all cells, without the temperature fluctuations that oversized chambers suffer.
- ✓Integrated software control through MITS, or manual control with the built-in LCD touchscreen.
- ✓Connections for a second voltage input or a PT100 temperature sensor for each main test channel.
- ✓Flexible cell fixturing for coin, cylindrical and pouch cells, with simple cabling between tester and cells.
- ✓Start and stop tests on an individual cell without affecting the others in the chamber.
Safty: 安全保护
- ✓Built-in over-temperature protection works with the Arbin tester to automatically stop tests on any cell that is out of tolerance.
- ✓Upper and lower temperature safety limits are set in MITS or on the touchscreen.
- ✓Each battery tray has a pressure relief valve, rated at 40 kPa (5.8 psi), for gassing or thermal events.
- ✓The interior of each zone is AISI 304 stainless steel, rated up to 925 °C, to contain a possible failure.
- ✓Non-spark fans, and heating elements that stay at or below 112 °C, prevent ignition of vented gas.
- ✓Two independent mechanical rotary door locks for each zone.
Questions about the MZTC
What temperature range does the MZTC cover?
Each zone can be set between 10 °C and 60 °C. The range also depends on the room: the lowest temperature a zone can reach is 10 °C below room temperature, and the highest is 40 °C above it. In a room at 20 °C the full range is available. Arbin recommends a room temperature between 18 °C and 28 °C.
Can the MZTC test below 10 °C or at sub-zero temperatures?
No. For testing below 10 °C or above 60 °C you need a conventional environmental chamber. Arbin testers can control many third-party chambers from the MITS software, so the chamber temperature can still be part of the test.
Can I use the MZTC with a battery tester from another company?
Yes. You connect the other tester's channels to the connectors on the trays and set the zone temperatures on the MZTC touchscreen. There is no software link between the MZTC and other testers, so the tester cannot set the temperature or react to it.
How is the MZTC different from an environmental chamber?
An environmental chamber is one large enclosure at one temperature, and it usually covers a wider range, including sub-zero temperatures. The MZTC has several small zones that can each be at a different temperature between 10 °C and 60 °C, and it includes the cell holders and the connections to the battery tester.
Tell us what you are testing