首页  ›  辅助功能模块  ›  多温区温箱 MZTC

Battery temperature chamber for cell testing

MZTC: Multi-Zone Temperature Chamber for Battery Cell Testing

The MZTC is a compact temperature chamber with 4 or 8 separate zones. Each zone holds one battery tray and is controlled independently between 10 °C and 60 °C, so cells can be tested at different temperatures at the same time.

4 or 8
Independent temperature zones
10 – 60 °C
Temperature range of every zone
±0.5 °C
Temperature control stability
Up to 60 A
Per cell, with trays for coin, cylindrical and pouch cells

Used next to an Arbin battery tester and controlled from MITS software, or stand-alone with the built-in touchscreen.

What the MZTC looks like

The chamber is 318 mm wide and stands on a bench or in a rack. Each zone has its own battery tray, which slides in from the front.

Front of the 8-zone MZTC with numbered parts 1 2 3 4 5 6 7
8-zone MZTC. One tray is shown removed from its zone.
  1. 1Touchscreen. Shows the set temperature and the measured temperature of every zone, and is used to set them when the chamber runs stand-alone.
  2. 2Zone. Each zone is insulated from the others and has its own temperature set point.
  3. 3Rotary door locks. Two locks hold each tray in place and keep the zone closed.
  4. 4Connectors. The cable from the tester channel plugs into the front of the tray.
  5. 5Open zone. The inside of each zone is stainless steel.
  6. 6Battery tray. The tray holds the cell and slides into the zone. Different trays are available for coin, cylindrical and pouch cells.
  7. 7Pressure relief valve. Each tray has a valve in the centre of its front panel, which opens if a cell releases gas.

How the MZTC works

1

Put the cell in a tray

Choose the tray for your cell: coin cell, cylindrical cell, or a universal tray for pouch cells. The tray holds the cell and makes the electrical contact.

2

Slide the tray into a zone and lock it

Two rotary locks close the zone. The connectors are on the front of the tray, so the cable from the tester plugs in from outside.

3

Set the temperature for that zone

Set each zone in the Arbin MITS software, or on the touchscreen. Each zone can have a different temperature.

A steady temperature in every zone. Air circulates inside each closed zone and keeps it at the set temperature, with a control stability of ±0.5 °C.
Zones that do not affect each other. The zones are insulated from one another, so each can hold a different temperature and a weak or failed cell does not disturb the others.
No building services. The chamber is air-cooled and runs from a single-phase outlet (100 to 240 VAC). It needs no chiller or cooling water.

Three ways to use the MZTC

The chamber is the same in each case. What changes is what it is connected to, and where the zone temperatures are set.

An Arbin battery tester with racks of MZTC chambers beside it
Most common

1. Next to an Arbin tester

The chamber stands beside the tester, and each tester channel is cabled to a tray. This is how most customers use the MZTC, and it can be quoted together with a new LBT system.

  • What Arbin suppliesThe chamber, the trays and the cables that match your tester channels
  • Where the temperature is setIn the MITS software, on the same PC that runs the test
  • If a cell goes out of rangeThe tester stops the test on that cell automatically
Request a quote for an LBT with MZTC →
MZTC rack shown empty and with three MZTC chambers installed
More zones

2. Several chambers in a rack

When one chamber is not enough, two or three chambers are stacked in a rack next to the tester. Each chamber is connected and controlled in the same way as a single one.

  • Rack sizesFor two chambers or for three chambers
  • Floor area23 in. by 30 in.
  • ConstructionAluminium frame, with casters as an option
An MZTC chamber on its own, with its touchscreen at the top
Without an Arbin tester

3. Stand-alone

The MZTC also works on its own as a temperature chamber, and it can be connected to a battery tester from another company.

  • Where the temperature is setOn the built-in touchscreen, which shows the set and measured temperature of every zone
  • Connection to another testerThrough the connectors on the trays
  • What is differentThe other tester cannot set or read the zone temperatures

The MZTC in customers' labs

MZTC chambers stacked three high in racks and cabled to a battery tester
Chambers stacked three high, with each tray cabled to a tester channel.
Rows of MZTC chambers installed in racks with their tester cables
A larger installation with several racks of chambers.

An example: one test at eight temperatures

Eight cells are placed in an 8-zone MZTC, one cell in each zone, and connected to the eight channels of an Arbin LBT tester. Every zone is given a different set point, from 15 °C to 50 °C, and all eight cells run the same test schedule at the same time.

The results for the eight temperatures can then be compared directly, because the cells were tested on the same days on the same tester. With a single conventional chamber the same study would need eight runs, one after the other.

Animated diagram: eight tester channels connected to eight MZTC zones, which move from room temperature to eight different set points between 15 and 50 degrees Celsius
The zones move from room temperature to eight different set points and then hold them while the test runs.
Temperature range. Each zone can be set from 10 °C to 60 °C, but no lower than 10 °C below room temperature and no higher than 40 °C above it. The MZTC does not test below 10 °C.
High-rate testing. For cells that give off a lot of heat during fast charging or high-current tests, ask us about the Smart Battery Tray (SBTR).

MZTC chamber models

There are three chambers. They work in the same way and differ in the number and size of the zones, so the choice depends on your cells.

温箱ZonesZone size (W × D × H)Chamber size (W × D × H)Weight
8-zone, 7-inch deepTrays for coin cells and for cylindrical cells up to 75 mm long 8 114 × 178 × 68 mm 318 × 407 × 560 mm 50 kg
8-zone, 10-inch deepTrays for cylindrical cells up to 100 mm long, including a tray for 46 mm cells 8 114 × 254 × 68 mm 318 × 483 × 635 mm 60 kg
4-zone, 10-inch deepWide zones, with trays for up to 16 coin cells or 4 cylindrical cells in one zone 4 270 × 254 × 68 mm 318 × 483 × 635 mm 60 kg
All three chambers have a temperature range of 10 °C to 60 °C and ±0.5 °C control stability, and run from a single-phase outlet (100 to 240 VAC). Which cells fit depends on the tray.

Full specifications are in the MZTC catalog. Ask us for the catalog →

Battery trays and cell formats

Trays are sold separately and chosen to match your cells and test current. Every tray works from 10 °C to 60 °C and has a pressure relief valve.

MZTC coin cell tray

Coin cell tray

  • Cells per tray2 or 4, 8 in the 10-inch chamber, and 16 in the 4-zone chamber
  • Maximum current5 A per cell
  • Cell size10 to 30 mm diameter, up to 7 mm high
MZTC two-cell cylindrical cell tray

Cylindrical cell tray, two cells

  • Cells per tray2
  • Maximum current10 A or 16 A per cell
  • Cell diameter18 to 32 mm (10 A tray), 18 to 26 mm (16 A tray)
  • Cell length55 to 75 mm, or 55 to 80 mm in the 10-inch chamber
  • Connection4-point Kelvin
MZTC single-cell cylindrical cell tray for 30 A or 60 A

Cylindrical cell tray, one cell

  • Cells per tray1
  • Maximum current30 A or 60 A
  • Cell size, 7-inch chamber18 to 32 mm diameter, 55 to 75 mm long
  • Cell size, 10-inch chamber18 to 50 mm diameter, 55 to 100 mm long
  • 46 mm trayFor the 10-inch chamber: 46 mm cells with both contacts on one side, 65 to 100 mm long, 60 A
  • Connection4-point Kelvin
MZTC universal cell tray for pouch cells

Universal tray

  • Cells per tray2 at 10 A, or 1 at 60 A
  • Used withA pouch-cell holder or alligator-clip leads
  • Space for the cellUnder 4 × 6.5 × 2.7 in., or 4 × 9.5 × 2.7 in. in the 10-inch chamber
  • Three-electrode version2 cells at 10 A
  • Connection4-point Kelvin

The full list of trays and cables is in the MZTC catalog. Ask us for the catalog →

Features and safety

功能介绍

  • ✓4 or 8 independent zones are isolated and allow a unique temperature set point.
  • ✓The patented design gives a stable and uniform temperature for all cells, without the temperature fluctuations that oversized chambers suffer.
  • ✓Integrated software control through MITS, or manual control with the built-in LCD touchscreen.
  • ✓Connections for a second voltage input or a PT100 temperature sensor for each main test channel.
  • ✓Flexible cell fixturing for coin, cylindrical and pouch cells, with simple cabling between tester and cells.
  • ✓Start and stop tests on an individual cell without affecting the others in the chamber.

Safty: 安全保护

  • ✓Built-in over-temperature protection works with the Arbin tester to automatically stop tests on any cell that is out of tolerance.
  • ✓Upper and lower temperature safety limits are set in MITS or on the touchscreen.
  • ✓Each battery tray has a pressure relief valve, rated at 40 kPa (5.8 psi), for gassing or thermal events.
  • ✓The interior of each zone is AISI 304 stainless steel, rated up to 925 °C, to contain a possible failure.
  • ✓Non-spark fans, and heating elements that stay at or below 112 °C, prevent ignition of vented gas.
  • ✓Two independent mechanical rotary door locks for each zone.

Questions about the MZTC

What temperature range does the MZTC cover?

Each zone can be set between 10 °C and 60 °C. The range also depends on the room: the lowest temperature a zone can reach is 10 °C below room temperature, and the highest is 40 °C above it. In a room at 20 °C the full range is available. Arbin recommends a room temperature between 18 °C and 28 °C.

Can the MZTC test below 10 °C or at sub-zero temperatures?

No. For testing below 10 °C or above 60 °C you need a conventional environmental chamber. Arbin testers can control many third-party chambers from the MITS software, so the chamber temperature can still be part of the test.

Can I use the MZTC with a battery tester from another company?

Yes. You connect the other tester's channels to the connectors on the trays and set the zone temperatures on the MZTC touchscreen. There is no software link between the MZTC and other testers, so the tester cannot set the temperature or react to it.

How is the MZTC different from an environmental chamber?

An environmental chamber is one large enclosure at one temperature, and it usually covers a wider range, including sub-zero temperatures. The MZTC has several small zones that can each be at a different temperature between 10 °C and 60 °C, and it includes the cell holders and the connections to the battery tester.

Tell us what you are testing

Send us your cell type and size, the test current, the temperatures you need, and the Arbin tester you have or plan to buy. A sales engineer will tell you which chamber, trays and cables you need.

滚动到顶部